blob: e3fa8118eaee16ec71ba58ab4cbb7f8422a1e68e [file] [log] [blame]
Qualcomm MSM8916 A53 PLL Binding
--------------------------------
The A53 PLL on MSM8916 platforms is the main CPU PLL used used for frequencies
above 1GHz.
Required properties :
- compatible : Shall contain only one of the following:
"qcom,msm8916-a53pll"
- reg : shall contain base register location and length
- #clock-cells : must be set to <0>
Example:
a53pll: clock@b016000 {
compatible = "qcom,msm8916-a53pll";
reg = <0xb016000 0x40>;
#clock-cells = <0>;
};