| // SPDX-License-Identifier: GPL-2.0 | 
 | /* | 
 |  * Device tree sources for Exynos4 thermal zone | 
 |  * | 
 |  * Copyright (c) 2014 Lukasz Majewski <l.majewski@samsung.com> | 
 |  */ | 
 |  | 
 | #include <dt-bindings/thermal/thermal.h> | 
 |  | 
 | / { | 
 | thermal-zones { | 
 | 	cpu_thermal: cpu-thermal { | 
 | 		thermal-sensors = <&tmu 0>; | 
 | 		polling-delay-passive = <0>; | 
 | 		polling-delay = <0>; | 
 | 		trips { | 
 | 			cpu_alert0: cpu-alert-0 { | 
 | 				temperature = <70000>; /* millicelsius */ | 
 | 				hysteresis = <10000>; /* millicelsius */ | 
 | 				type = "active"; | 
 | 			}; | 
 | 			cpu_alert1: cpu-alert-1 { | 
 | 				temperature = <95000>; /* millicelsius */ | 
 | 				hysteresis = <10000>; /* millicelsius */ | 
 | 				type = "active"; | 
 | 			}; | 
 | 			cpu_alert2: cpu-alert-2 { | 
 | 				temperature = <110000>; /* millicelsius */ | 
 | 				hysteresis = <10000>; /* millicelsius */ | 
 | 				type = "active"; | 
 | 			}; | 
 | 			cpu_crit0: cpu-crit-0 { | 
 | 				temperature = <120000>; /* millicelsius */ | 
 | 				hysteresis = <0>; /* millicelsius */ | 
 | 				type = "critical"; | 
 | 			}; | 
 | 		}; | 
 | 		cooling-maps { | 
 | 			map0 { | 
 | 				trip = <&cpu_alert0>; | 
 | 			}; | 
 | 			map1 { | 
 | 				trip = <&cpu_alert1>; | 
 | 			}; | 
 | 		}; | 
 | 	}; | 
 | }; | 
 | }; |