| // SPDX-License-Identifier: GPL-2.0 | 
 | /* | 
 |  *  linux/drivers/thermal/cpufreq_cooling.c | 
 |  * | 
 |  *  Copyright (C) 2012	Samsung Electronics Co., Ltd(http://www.samsung.com) | 
 |  * | 
 |  *  Copyright (C) 2012-2018 Linaro Limited. | 
 |  * | 
 |  *  Authors:	Amit Daniel <amit.kachhap@linaro.org> | 
 |  *		Viresh Kumar <viresh.kumar@linaro.org> | 
 |  * | 
 |  */ | 
 | #include <linux/cpu.h> | 
 | #include <linux/cpufreq.h> | 
 | #include <linux/cpu_cooling.h> | 
 | #include <linux/device.h> | 
 | #include <linux/energy_model.h> | 
 | #include <linux/err.h> | 
 | #include <linux/export.h> | 
 | #include <linux/pm_opp.h> | 
 | #include <linux/pm_qos.h> | 
 | #include <linux/slab.h> | 
 | #include <linux/thermal.h> | 
 |  | 
 | #include <trace/events/thermal.h> | 
 |  | 
 | /* | 
 |  * Cooling state <-> CPUFreq frequency | 
 |  * | 
 |  * Cooling states are translated to frequencies throughout this driver and this | 
 |  * is the relation between them. | 
 |  * | 
 |  * Highest cooling state corresponds to lowest possible frequency. | 
 |  * | 
 |  * i.e. | 
 |  *	level 0 --> 1st Max Freq | 
 |  *	level 1 --> 2nd Max Freq | 
 |  *	... | 
 |  */ | 
 |  | 
 | /** | 
 |  * struct time_in_idle - Idle time stats | 
 |  * @time: previous reading of the absolute time that this cpu was idle | 
 |  * @timestamp: wall time of the last invocation of get_cpu_idle_time_us() | 
 |  */ | 
 | struct time_in_idle { | 
 | 	u64 time; | 
 | 	u64 timestamp; | 
 | }; | 
 |  | 
 | /** | 
 |  * struct cpufreq_cooling_device - data for cooling device with cpufreq | 
 |  * @last_load: load measured by the latest call to cpufreq_get_requested_power() | 
 |  * @cpufreq_state: integer value representing the current state of cpufreq | 
 |  *	cooling	devices. | 
 |  * @max_level: maximum cooling level. One less than total number of valid | 
 |  *	cpufreq frequencies. | 
 |  * @em: Reference on the Energy Model of the device | 
 |  * @cdev: thermal_cooling_device pointer to keep track of the | 
 |  *	registered cooling device. | 
 |  * @policy: cpufreq policy. | 
 |  * @idle_time: idle time stats | 
 |  * @qos_req: PM QoS contraint to apply | 
 |  * | 
 |  * This structure is required for keeping information of each registered | 
 |  * cpufreq_cooling_device. | 
 |  */ | 
 | struct cpufreq_cooling_device { | 
 | 	u32 last_load; | 
 | 	unsigned int cpufreq_state; | 
 | 	unsigned int max_level; | 
 | 	struct em_perf_domain *em; | 
 | 	struct cpufreq_policy *policy; | 
 | #ifndef CONFIG_SMP | 
 | 	struct time_in_idle *idle_time; | 
 | #endif | 
 | 	struct freq_qos_request qos_req; | 
 | }; | 
 |  | 
 | #ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR | 
 | /** | 
 |  * get_level: Find the level for a particular frequency | 
 |  * @cpufreq_cdev: cpufreq_cdev for which the property is required | 
 |  * @freq: Frequency | 
 |  * | 
 |  * Return: level corresponding to the frequency. | 
 |  */ | 
 | static unsigned long get_level(struct cpufreq_cooling_device *cpufreq_cdev, | 
 | 			       unsigned int freq) | 
 | { | 
 | 	int i; | 
 |  | 
 | 	for (i = cpufreq_cdev->max_level - 1; i >= 0; i--) { | 
 | 		if (freq > cpufreq_cdev->em->table[i].frequency) | 
 | 			break; | 
 | 	} | 
 |  | 
 | 	return cpufreq_cdev->max_level - i - 1; | 
 | } | 
 |  | 
 | static u32 cpu_freq_to_power(struct cpufreq_cooling_device *cpufreq_cdev, | 
 | 			     u32 freq) | 
 | { | 
 | 	int i; | 
 |  | 
 | 	for (i = cpufreq_cdev->max_level - 1; i >= 0; i--) { | 
 | 		if (freq > cpufreq_cdev->em->table[i].frequency) | 
 | 			break; | 
 | 	} | 
 |  | 
 | 	return cpufreq_cdev->em->table[i + 1].power; | 
 | } | 
 |  | 
 | static u32 cpu_power_to_freq(struct cpufreq_cooling_device *cpufreq_cdev, | 
 | 			     u32 power) | 
 | { | 
 | 	int i; | 
 |  | 
 | 	for (i = cpufreq_cdev->max_level; i > 0; i--) { | 
 | 		if (power >= cpufreq_cdev->em->table[i].power) | 
 | 			break; | 
 | 	} | 
 |  | 
 | 	return cpufreq_cdev->em->table[i].frequency; | 
 | } | 
 |  | 
 | /** | 
 |  * get_load() - get load for a cpu | 
 |  * @cpufreq_cdev: struct cpufreq_cooling_device for the cpu | 
 |  * @cpu: cpu number | 
 |  * @cpu_idx: index of the cpu in time_in_idle array | 
 |  * | 
 |  * Return: The average load of cpu @cpu in percentage since this | 
 |  * function was last called. | 
 |  */ | 
 | #ifdef CONFIG_SMP | 
 | static u32 get_load(struct cpufreq_cooling_device *cpufreq_cdev, int cpu, | 
 | 		    int cpu_idx) | 
 | { | 
 | 	unsigned long max = arch_scale_cpu_capacity(cpu); | 
 | 	unsigned long util; | 
 |  | 
 | 	util = sched_cpu_util(cpu, max); | 
 | 	return (util * 100) / max; | 
 | } | 
 | #else /* !CONFIG_SMP */ | 
 | static u32 get_load(struct cpufreq_cooling_device *cpufreq_cdev, int cpu, | 
 | 		    int cpu_idx) | 
 | { | 
 | 	u32 load; | 
 | 	u64 now, now_idle, delta_time, delta_idle; | 
 | 	struct time_in_idle *idle_time = &cpufreq_cdev->idle_time[cpu_idx]; | 
 |  | 
 | 	now_idle = get_cpu_idle_time(cpu, &now, 0); | 
 | 	delta_idle = now_idle - idle_time->time; | 
 | 	delta_time = now - idle_time->timestamp; | 
 |  | 
 | 	if (delta_time <= delta_idle) | 
 | 		load = 0; | 
 | 	else | 
 | 		load = div64_u64(100 * (delta_time - delta_idle), delta_time); | 
 |  | 
 | 	idle_time->time = now_idle; | 
 | 	idle_time->timestamp = now; | 
 |  | 
 | 	return load; | 
 | } | 
 | #endif /* CONFIG_SMP */ | 
 |  | 
 | /** | 
 |  * get_dynamic_power() - calculate the dynamic power | 
 |  * @cpufreq_cdev:	&cpufreq_cooling_device for this cdev | 
 |  * @freq:	current frequency | 
 |  * | 
 |  * Return: the dynamic power consumed by the cpus described by | 
 |  * @cpufreq_cdev. | 
 |  */ | 
 | static u32 get_dynamic_power(struct cpufreq_cooling_device *cpufreq_cdev, | 
 | 			     unsigned long freq) | 
 | { | 
 | 	u32 raw_cpu_power; | 
 |  | 
 | 	raw_cpu_power = cpu_freq_to_power(cpufreq_cdev, freq); | 
 | 	return (raw_cpu_power * cpufreq_cdev->last_load) / 100; | 
 | } | 
 |  | 
 | /** | 
 |  * cpufreq_get_requested_power() - get the current power | 
 |  * @cdev:	&thermal_cooling_device pointer | 
 |  * @power:	pointer in which to store the resulting power | 
 |  * | 
 |  * Calculate the current power consumption of the cpus in milliwatts | 
 |  * and store it in @power.  This function should actually calculate | 
 |  * the requested power, but it's hard to get the frequency that | 
 |  * cpufreq would have assigned if there were no thermal limits. | 
 |  * Instead, we calculate the current power on the assumption that the | 
 |  * immediate future will look like the immediate past. | 
 |  * | 
 |  * We use the current frequency and the average load since this | 
 |  * function was last called.  In reality, there could have been | 
 |  * multiple opps since this function was last called and that affects | 
 |  * the load calculation.  While it's not perfectly accurate, this | 
 |  * simplification is good enough and works.  REVISIT this, as more | 
 |  * complex code may be needed if experiments show that it's not | 
 |  * accurate enough. | 
 |  * | 
 |  * Return: 0 on success, -E* if getting the static power failed. | 
 |  */ | 
 | static int cpufreq_get_requested_power(struct thermal_cooling_device *cdev, | 
 | 				       u32 *power) | 
 | { | 
 | 	unsigned long freq; | 
 | 	int i = 0, cpu; | 
 | 	u32 total_load = 0; | 
 | 	struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; | 
 | 	struct cpufreq_policy *policy = cpufreq_cdev->policy; | 
 | 	u32 *load_cpu = NULL; | 
 |  | 
 | 	freq = cpufreq_quick_get(policy->cpu); | 
 |  | 
 | 	if (trace_thermal_power_cpu_get_power_enabled()) { | 
 | 		u32 ncpus = cpumask_weight(policy->related_cpus); | 
 |  | 
 | 		load_cpu = kcalloc(ncpus, sizeof(*load_cpu), GFP_KERNEL); | 
 | 	} | 
 |  | 
 | 	for_each_cpu(cpu, policy->related_cpus) { | 
 | 		u32 load; | 
 |  | 
 | 		if (cpu_online(cpu)) | 
 | 			load = get_load(cpufreq_cdev, cpu, i); | 
 | 		else | 
 | 			load = 0; | 
 |  | 
 | 		total_load += load; | 
 | 		if (load_cpu) | 
 | 			load_cpu[i] = load; | 
 |  | 
 | 		i++; | 
 | 	} | 
 |  | 
 | 	cpufreq_cdev->last_load = total_load; | 
 |  | 
 | 	*power = get_dynamic_power(cpufreq_cdev, freq); | 
 |  | 
 | 	if (load_cpu) { | 
 | 		trace_thermal_power_cpu_get_power(policy->related_cpus, freq, | 
 | 						  load_cpu, i, *power); | 
 |  | 
 | 		kfree(load_cpu); | 
 | 	} | 
 |  | 
 | 	return 0; | 
 | } | 
 |  | 
 | /** | 
 |  * cpufreq_state2power() - convert a cpu cdev state to power consumed | 
 |  * @cdev:	&thermal_cooling_device pointer | 
 |  * @state:	cooling device state to be converted | 
 |  * @power:	pointer in which to store the resulting power | 
 |  * | 
 |  * Convert cooling device state @state into power consumption in | 
 |  * milliwatts assuming 100% load.  Store the calculated power in | 
 |  * @power. | 
 |  * | 
 |  * Return: 0 on success, -EINVAL if the cooling device state could not | 
 |  * be converted into a frequency or other -E* if there was an error | 
 |  * when calculating the static power. | 
 |  */ | 
 | static int cpufreq_state2power(struct thermal_cooling_device *cdev, | 
 | 			       unsigned long state, u32 *power) | 
 | { | 
 | 	unsigned int freq, num_cpus, idx; | 
 | 	struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; | 
 |  | 
 | 	/* Request state should be less than max_level */ | 
 | 	if (state > cpufreq_cdev->max_level) | 
 | 		return -EINVAL; | 
 |  | 
 | 	num_cpus = cpumask_weight(cpufreq_cdev->policy->cpus); | 
 |  | 
 | 	idx = cpufreq_cdev->max_level - state; | 
 | 	freq = cpufreq_cdev->em->table[idx].frequency; | 
 | 	*power = cpu_freq_to_power(cpufreq_cdev, freq) * num_cpus; | 
 |  | 
 | 	return 0; | 
 | } | 
 |  | 
 | /** | 
 |  * cpufreq_power2state() - convert power to a cooling device state | 
 |  * @cdev:	&thermal_cooling_device pointer | 
 |  * @power:	power in milliwatts to be converted | 
 |  * @state:	pointer in which to store the resulting state | 
 |  * | 
 |  * Calculate a cooling device state for the cpus described by @cdev | 
 |  * that would allow them to consume at most @power mW and store it in | 
 |  * @state.  Note that this calculation depends on external factors | 
 |  * such as the cpu load or the current static power.  Calling this | 
 |  * function with the same power as input can yield different cooling | 
 |  * device states depending on those external factors. | 
 |  * | 
 |  * Return: 0 on success, -ENODEV if no cpus are online or -EINVAL if | 
 |  * the calculated frequency could not be converted to a valid state. | 
 |  * The latter should not happen unless the frequencies available to | 
 |  * cpufreq have changed since the initialization of the cpu cooling | 
 |  * device. | 
 |  */ | 
 | static int cpufreq_power2state(struct thermal_cooling_device *cdev, | 
 | 			       u32 power, unsigned long *state) | 
 | { | 
 | 	unsigned int target_freq; | 
 | 	u32 last_load, normalised_power; | 
 | 	struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; | 
 | 	struct cpufreq_policy *policy = cpufreq_cdev->policy; | 
 |  | 
 | 	last_load = cpufreq_cdev->last_load ?: 1; | 
 | 	normalised_power = (power * 100) / last_load; | 
 | 	target_freq = cpu_power_to_freq(cpufreq_cdev, normalised_power); | 
 |  | 
 | 	*state = get_level(cpufreq_cdev, target_freq); | 
 | 	trace_thermal_power_cpu_limit(policy->related_cpus, target_freq, *state, | 
 | 				      power); | 
 | 	return 0; | 
 | } | 
 |  | 
 | static inline bool em_is_sane(struct cpufreq_cooling_device *cpufreq_cdev, | 
 | 			      struct em_perf_domain *em) { | 
 | 	struct cpufreq_policy *policy; | 
 | 	unsigned int nr_levels; | 
 |  | 
 | 	if (!em) | 
 | 		return false; | 
 |  | 
 | 	policy = cpufreq_cdev->policy; | 
 | 	if (!cpumask_equal(policy->related_cpus, em_span_cpus(em))) { | 
 | 		pr_err("The span of pd %*pbl is misaligned with cpufreq policy %*pbl\n", | 
 | 			cpumask_pr_args(em_span_cpus(em)), | 
 | 			cpumask_pr_args(policy->related_cpus)); | 
 | 		return false; | 
 | 	} | 
 |  | 
 | 	nr_levels = cpufreq_cdev->max_level + 1; | 
 | 	if (em_pd_nr_perf_states(em) != nr_levels) { | 
 | 		pr_err("The number of performance states in pd %*pbl (%u) doesn't match the number of cooling levels (%u)\n", | 
 | 			cpumask_pr_args(em_span_cpus(em)), | 
 | 			em_pd_nr_perf_states(em), nr_levels); | 
 | 		return false; | 
 | 	} | 
 |  | 
 | 	return true; | 
 | } | 
 | #endif /* CONFIG_THERMAL_GOV_POWER_ALLOCATOR */ | 
 |  | 
 | #ifdef CONFIG_SMP | 
 | static inline int allocate_idle_time(struct cpufreq_cooling_device *cpufreq_cdev) | 
 | { | 
 | 	return 0; | 
 | } | 
 |  | 
 | static inline void free_idle_time(struct cpufreq_cooling_device *cpufreq_cdev) | 
 | { | 
 | } | 
 | #else | 
 | static int allocate_idle_time(struct cpufreq_cooling_device *cpufreq_cdev) | 
 | { | 
 | 	unsigned int num_cpus = cpumask_weight(cpufreq_cdev->policy->related_cpus); | 
 |  | 
 | 	cpufreq_cdev->idle_time = kcalloc(num_cpus, | 
 | 					  sizeof(*cpufreq_cdev->idle_time), | 
 | 					  GFP_KERNEL); | 
 | 	if (!cpufreq_cdev->idle_time) | 
 | 		return -ENOMEM; | 
 |  | 
 | 	return 0; | 
 | } | 
 |  | 
 | static void free_idle_time(struct cpufreq_cooling_device *cpufreq_cdev) | 
 | { | 
 | 	kfree(cpufreq_cdev->idle_time); | 
 | 	cpufreq_cdev->idle_time = NULL; | 
 | } | 
 | #endif /* CONFIG_SMP */ | 
 |  | 
 | static unsigned int get_state_freq(struct cpufreq_cooling_device *cpufreq_cdev, | 
 | 				   unsigned long state) | 
 | { | 
 | 	struct cpufreq_policy *policy; | 
 | 	unsigned long idx; | 
 |  | 
 | #ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR | 
 | 	/* Use the Energy Model table if available */ | 
 | 	if (cpufreq_cdev->em) { | 
 | 		idx = cpufreq_cdev->max_level - state; | 
 | 		return cpufreq_cdev->em->table[idx].frequency; | 
 | 	} | 
 | #endif | 
 |  | 
 | 	/* Otherwise, fallback on the CPUFreq table */ | 
 | 	policy = cpufreq_cdev->policy; | 
 | 	if (policy->freq_table_sorted == CPUFREQ_TABLE_SORTED_ASCENDING) | 
 | 		idx = cpufreq_cdev->max_level - state; | 
 | 	else | 
 | 		idx = state; | 
 |  | 
 | 	return policy->freq_table[idx].frequency; | 
 | } | 
 |  | 
 | /* cpufreq cooling device callback functions are defined below */ | 
 |  | 
 | /** | 
 |  * cpufreq_get_max_state - callback function to get the max cooling state. | 
 |  * @cdev: thermal cooling device pointer. | 
 |  * @state: fill this variable with the max cooling state. | 
 |  * | 
 |  * Callback for the thermal cooling device to return the cpufreq | 
 |  * max cooling state. | 
 |  * | 
 |  * Return: 0 on success, an error code otherwise. | 
 |  */ | 
 | static int cpufreq_get_max_state(struct thermal_cooling_device *cdev, | 
 | 				 unsigned long *state) | 
 | { | 
 | 	struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; | 
 |  | 
 | 	*state = cpufreq_cdev->max_level; | 
 | 	return 0; | 
 | } | 
 |  | 
 | /** | 
 |  * cpufreq_get_cur_state - callback function to get the current cooling state. | 
 |  * @cdev: thermal cooling device pointer. | 
 |  * @state: fill this variable with the current cooling state. | 
 |  * | 
 |  * Callback for the thermal cooling device to return the cpufreq | 
 |  * current cooling state. | 
 |  * | 
 |  * Return: 0 on success, an error code otherwise. | 
 |  */ | 
 | static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev, | 
 | 				 unsigned long *state) | 
 | { | 
 | 	struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; | 
 |  | 
 | 	*state = cpufreq_cdev->cpufreq_state; | 
 |  | 
 | 	return 0; | 
 | } | 
 |  | 
 | /** | 
 |  * cpufreq_set_cur_state - callback function to set the current cooling state. | 
 |  * @cdev: thermal cooling device pointer. | 
 |  * @state: set this variable to the current cooling state. | 
 |  * | 
 |  * Callback for the thermal cooling device to change the cpufreq | 
 |  * current cooling state. | 
 |  * | 
 |  * Return: 0 on success, an error code otherwise. | 
 |  */ | 
 | static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, | 
 | 				 unsigned long state) | 
 | { | 
 | 	struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; | 
 | 	struct cpumask *cpus; | 
 | 	unsigned int frequency; | 
 | 	unsigned long max_capacity, capacity; | 
 | 	int ret; | 
 |  | 
 | 	/* Request state should be less than max_level */ | 
 | 	if (state > cpufreq_cdev->max_level) | 
 | 		return -EINVAL; | 
 |  | 
 | 	/* Check if the old cooling action is same as new cooling action */ | 
 | 	if (cpufreq_cdev->cpufreq_state == state) | 
 | 		return 0; | 
 |  | 
 | 	frequency = get_state_freq(cpufreq_cdev, state); | 
 |  | 
 | 	ret = freq_qos_update_request(&cpufreq_cdev->qos_req, frequency); | 
 | 	if (ret >= 0) { | 
 | 		cpufreq_cdev->cpufreq_state = state; | 
 | 		cpus = cpufreq_cdev->policy->related_cpus; | 
 | 		max_capacity = arch_scale_cpu_capacity(cpumask_first(cpus)); | 
 | 		capacity = frequency * max_capacity; | 
 | 		capacity /= cpufreq_cdev->policy->cpuinfo.max_freq; | 
 | 		arch_set_thermal_pressure(cpus, max_capacity - capacity); | 
 | 		ret = 0; | 
 | 	} | 
 |  | 
 | 	return ret; | 
 | } | 
 |  | 
 | /* Bind cpufreq callbacks to thermal cooling device ops */ | 
 |  | 
 | static struct thermal_cooling_device_ops cpufreq_cooling_ops = { | 
 | 	.get_max_state		= cpufreq_get_max_state, | 
 | 	.get_cur_state		= cpufreq_get_cur_state, | 
 | 	.set_cur_state		= cpufreq_set_cur_state, | 
 | }; | 
 |  | 
 | /** | 
 |  * __cpufreq_cooling_register - helper function to create cpufreq cooling device | 
 |  * @np: a valid struct device_node to the cooling device device tree node | 
 |  * @policy: cpufreq policy | 
 |  * Normally this should be same as cpufreq policy->related_cpus. | 
 |  * @em: Energy Model of the cpufreq policy | 
 |  * | 
 |  * This interface function registers the cpufreq cooling device with the name | 
 |  * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq | 
 |  * cooling devices. It also gives the opportunity to link the cooling device | 
 |  * with a device tree node, in order to bind it via the thermal DT code. | 
 |  * | 
 |  * Return: a valid struct thermal_cooling_device pointer on success, | 
 |  * on failure, it returns a corresponding ERR_PTR(). | 
 |  */ | 
 | static struct thermal_cooling_device * | 
 | __cpufreq_cooling_register(struct device_node *np, | 
 | 			struct cpufreq_policy *policy, | 
 | 			struct em_perf_domain *em) | 
 | { | 
 | 	struct thermal_cooling_device *cdev; | 
 | 	struct cpufreq_cooling_device *cpufreq_cdev; | 
 | 	unsigned int i; | 
 | 	struct device *dev; | 
 | 	int ret; | 
 | 	struct thermal_cooling_device_ops *cooling_ops; | 
 | 	char *name; | 
 |  | 
 | 	dev = get_cpu_device(policy->cpu); | 
 | 	if (unlikely(!dev)) { | 
 | 		pr_warn("No cpu device for cpu %d\n", policy->cpu); | 
 | 		return ERR_PTR(-ENODEV); | 
 | 	} | 
 |  | 
 | 	if (IS_ERR_OR_NULL(policy)) { | 
 | 		pr_err("%s: cpufreq policy isn't valid: %p\n", __func__, policy); | 
 | 		return ERR_PTR(-EINVAL); | 
 | 	} | 
 |  | 
 | 	i = cpufreq_table_count_valid_entries(policy); | 
 | 	if (!i) { | 
 | 		pr_debug("%s: CPUFreq table not found or has no valid entries\n", | 
 | 			 __func__); | 
 | 		return ERR_PTR(-ENODEV); | 
 | 	} | 
 |  | 
 | 	cpufreq_cdev = kzalloc(sizeof(*cpufreq_cdev), GFP_KERNEL); | 
 | 	if (!cpufreq_cdev) | 
 | 		return ERR_PTR(-ENOMEM); | 
 |  | 
 | 	cpufreq_cdev->policy = policy; | 
 |  | 
 | 	ret = allocate_idle_time(cpufreq_cdev); | 
 | 	if (ret) { | 
 | 		cdev = ERR_PTR(ret); | 
 | 		goto free_cdev; | 
 | 	} | 
 |  | 
 | 	/* max_level is an index, not a counter */ | 
 | 	cpufreq_cdev->max_level = i - 1; | 
 |  | 
 | 	cooling_ops = &cpufreq_cooling_ops; | 
 |  | 
 | #ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR | 
 | 	if (em_is_sane(cpufreq_cdev, em)) { | 
 | 		cpufreq_cdev->em = em; | 
 | 		cooling_ops->get_requested_power = cpufreq_get_requested_power; | 
 | 		cooling_ops->state2power = cpufreq_state2power; | 
 | 		cooling_ops->power2state = cpufreq_power2state; | 
 | 	} else | 
 | #endif | 
 | 	if (policy->freq_table_sorted == CPUFREQ_TABLE_UNSORTED) { | 
 | 		pr_err("%s: unsorted frequency tables are not supported\n", | 
 | 		       __func__); | 
 | 		cdev = ERR_PTR(-EINVAL); | 
 | 		goto free_idle_time; | 
 | 	} | 
 |  | 
 | 	ret = freq_qos_add_request(&policy->constraints, | 
 | 				   &cpufreq_cdev->qos_req, FREQ_QOS_MAX, | 
 | 				   get_state_freq(cpufreq_cdev, 0)); | 
 | 	if (ret < 0) { | 
 | 		pr_err("%s: Failed to add freq constraint (%d)\n", __func__, | 
 | 		       ret); | 
 | 		cdev = ERR_PTR(ret); | 
 | 		goto free_idle_time; | 
 | 	} | 
 |  | 
 | 	cdev = ERR_PTR(-ENOMEM); | 
 | 	name = kasprintf(GFP_KERNEL, "cpufreq-%s", dev_name(dev)); | 
 | 	if (!name) | 
 | 		goto remove_qos_req; | 
 |  | 
 | 	cdev = thermal_of_cooling_device_register(np, name, cpufreq_cdev, | 
 | 						  cooling_ops); | 
 | 	kfree(name); | 
 |  | 
 | 	if (IS_ERR(cdev)) | 
 | 		goto remove_qos_req; | 
 |  | 
 | 	return cdev; | 
 |  | 
 | remove_qos_req: | 
 | 	freq_qos_remove_request(&cpufreq_cdev->qos_req); | 
 | free_idle_time: | 
 | 	free_idle_time(cpufreq_cdev); | 
 | free_cdev: | 
 | 	kfree(cpufreq_cdev); | 
 | 	return cdev; | 
 | } | 
 |  | 
 | /** | 
 |  * cpufreq_cooling_register - function to create cpufreq cooling device. | 
 |  * @policy: cpufreq policy | 
 |  * | 
 |  * This interface function registers the cpufreq cooling device with the name | 
 |  * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq | 
 |  * cooling devices. | 
 |  * | 
 |  * Return: a valid struct thermal_cooling_device pointer on success, | 
 |  * on failure, it returns a corresponding ERR_PTR(). | 
 |  */ | 
 | struct thermal_cooling_device * | 
 | cpufreq_cooling_register(struct cpufreq_policy *policy) | 
 | { | 
 | 	return __cpufreq_cooling_register(NULL, policy, NULL); | 
 | } | 
 | EXPORT_SYMBOL_GPL(cpufreq_cooling_register); | 
 |  | 
 | /** | 
 |  * of_cpufreq_cooling_register - function to create cpufreq cooling device. | 
 |  * @policy: cpufreq policy | 
 |  * | 
 |  * This interface function registers the cpufreq cooling device with the name | 
 |  * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq | 
 |  * cooling devices. Using this API, the cpufreq cooling device will be | 
 |  * linked to the device tree node provided. | 
 |  * | 
 |  * Using this function, the cooling device will implement the power | 
 |  * extensions by using a simple cpu power model.  The cpus must have | 
 |  * registered their OPPs using the OPP library. | 
 |  * | 
 |  * It also takes into account, if property present in policy CPU node, the | 
 |  * static power consumed by the cpu. | 
 |  * | 
 |  * Return: a valid struct thermal_cooling_device pointer on success, | 
 |  * and NULL on failure. | 
 |  */ | 
 | struct thermal_cooling_device * | 
 | of_cpufreq_cooling_register(struct cpufreq_policy *policy) | 
 | { | 
 | 	struct device_node *np = of_get_cpu_node(policy->cpu, NULL); | 
 | 	struct thermal_cooling_device *cdev = NULL; | 
 |  | 
 | 	if (!np) { | 
 | 		pr_err("cpufreq_cooling: OF node not available for cpu%d\n", | 
 | 		       policy->cpu); | 
 | 		return NULL; | 
 | 	} | 
 |  | 
 | 	if (of_find_property(np, "#cooling-cells", NULL)) { | 
 | 		struct em_perf_domain *em = em_cpu_get(policy->cpu); | 
 |  | 
 | 		cdev = __cpufreq_cooling_register(np, policy, em); | 
 | 		if (IS_ERR(cdev)) { | 
 | 			pr_err("cpufreq_cooling: cpu%d failed to register as cooling device: %ld\n", | 
 | 			       policy->cpu, PTR_ERR(cdev)); | 
 | 			cdev = NULL; | 
 | 		} | 
 | 	} | 
 |  | 
 | 	of_node_put(np); | 
 | 	return cdev; | 
 | } | 
 | EXPORT_SYMBOL_GPL(of_cpufreq_cooling_register); | 
 |  | 
 | /** | 
 |  * cpufreq_cooling_unregister - function to remove cpufreq cooling device. | 
 |  * @cdev: thermal cooling device pointer. | 
 |  * | 
 |  * This interface function unregisters the "thermal-cpufreq-%x" cooling device. | 
 |  */ | 
 | void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) | 
 | { | 
 | 	struct cpufreq_cooling_device *cpufreq_cdev; | 
 |  | 
 | 	if (!cdev) | 
 | 		return; | 
 |  | 
 | 	cpufreq_cdev = cdev->devdata; | 
 |  | 
 | 	thermal_cooling_device_unregister(cdev); | 
 | 	freq_qos_remove_request(&cpufreq_cdev->qos_req); | 
 | 	free_idle_time(cpufreq_cdev); | 
 | 	kfree(cpufreq_cdev); | 
 | } | 
 | EXPORT_SYMBOL_GPL(cpufreq_cooling_unregister); |