| NVIDIA Tegra410 SoC Uncore Performance Monitoring Unit (PMU) |
| ===================================================================== |
| |
| The NVIDIA Tegra410 SoC includes various system PMUs to measure key performance |
| metrics like memory bandwidth, latency, and utilization: |
| |
| * Unified Coherence Fabric (UCF) |
| * PCIE |
| * PCIE-TGT |
| * CPU Memory (CMEM) Latency |
| * NVLink-C2C |
| * NV-CLink |
| * NV-DLink |
| |
| PMU Driver |
| ---------- |
| |
| The PMU driver describes the available events and configuration of each PMU in |
| sysfs. Please see the sections below to get the sysfs path of each PMU. Like |
| other uncore PMU drivers, the driver provides "cpumask" sysfs attribute to show |
| the CPU id used to handle the PMU event. There is also "associated_cpus" |
| sysfs attribute, which contains a list of CPUs associated with the PMU instance. |
| |
| UCF PMU |
| ------- |
| |
| The Unified Coherence Fabric (UCF) in the NVIDIA Tegra410 SoC serves as a |
| distributed cache, last level for CPU Memory and CXL Memory, and cache coherent |
| interconnect that supports hardware coherence across multiple coherently caching |
| agents, including: |
| |
| * CPU clusters |
| * GPU |
| * PCIe Ordering Controller Unit (OCU) |
| * Other IO-coherent requesters |
| |
| The events and configuration options of this PMU device are described in sysfs, |
| see /sys/bus/event_source/devices/nvidia_ucf_pmu_<socket-id>. |
| |
| Some of the events available in this PMU can be used to measure bandwidth and |
| utilization: |
| |
| * slc_access_rd: count the number of read requests to SLC. |
| * slc_access_wr: count the number of write requests to SLC. |
| * slc_bytes_rd: count the number of bytes transferred by slc_access_rd. |
| * slc_bytes_wr: count the number of bytes transferred by slc_access_wr. |
| * mem_access_rd: count the number of read requests to local or remote memory. |
| * mem_access_wr: count the number of write requests to local or remote memory. |
| * mem_bytes_rd: count the number of bytes transferred by mem_access_rd. |
| * mem_bytes_wr: count the number of bytes transferred by mem_access_wr. |
| * cycles: counts the UCF cycles. |
| |
| The average bandwidth is calculated as:: |
| |
| AVG_SLC_READ_BANDWIDTH_IN_GBPS = SLC_BYTES_RD / ELAPSED_TIME_IN_NS |
| AVG_SLC_WRITE_BANDWIDTH_IN_GBPS = SLC_BYTES_WR / ELAPSED_TIME_IN_NS |
| AVG_MEM_READ_BANDWIDTH_IN_GBPS = MEM_BYTES_RD / ELAPSED_TIME_IN_NS |
| AVG_MEM_WRITE_BANDWIDTH_IN_GBPS = MEM_BYTES_WR / ELAPSED_TIME_IN_NS |
| |
| The average request rate is calculated as:: |
| |
| AVG_SLC_READ_REQUEST_RATE = SLC_ACCESS_RD / CYCLES |
| AVG_SLC_WRITE_REQUEST_RATE = SLC_ACCESS_WR / CYCLES |
| AVG_MEM_READ_REQUEST_RATE = MEM_ACCESS_RD / CYCLES |
| AVG_MEM_WRITE_REQUEST_RATE = MEM_ACCESS_WR / CYCLES |
| |
| More details about what other events are available can be found in Tegra410 SoC |
| technical reference manual. |
| |
| The events can be filtered based on source or destination. The source filter |
| indicates the traffic initiator to the SLC, e.g local CPU, non-CPU device, or |
| remote socket. The destination filter specifies the destination memory type, |
| e.g. local system memory (CMEM), local GPU memory (GMEM), or remote memory. The |
| local/remote classification of the destination filter is based on the home |
| socket of the address, not where the data actually resides. The available |
| filters are described in |
| /sys/bus/event_source/devices/nvidia_ucf_pmu_<socket-id>/format/. |
| |
| The list of UCF PMU event filters: |
| |
| * Source filter: |
| |
| * src_loc_cpu: if set, count events from local CPU |
| * src_loc_noncpu: if set, count events from local non-CPU device |
| * src_rem: if set, count events from CPU, GPU, PCIE devices of remote socket |
| |
| * Destination filter: |
| |
| * dst_loc_cmem: if set, count events to local system memory (CMEM) address |
| * dst_loc_gmem: if set, count events to local GPU memory (GMEM) address |
| * dst_loc_other: if set, count events to local CXL memory address |
| * dst_rem: if set, count events to CPU, GPU, and CXL memory address of remote socket |
| |
| If the source is not specified, the PMU will count events from all sources. If |
| the destination is not specified, the PMU will count events to all destinations. |
| |
| Example usage: |
| |
| * Count event id 0x0 in socket 0 from all sources and to all destinations:: |
| |
| perf stat -a -e nvidia_ucf_pmu_0/event=0x0/ |
| |
| * Count event id 0x0 in socket 0 with source filter = local CPU and destination |
| filter = local system memory (CMEM):: |
| |
| perf stat -a -e nvidia_ucf_pmu_0/event=0x0,src_loc_cpu=0x1,dst_loc_cmem=0x1/ |
| |
| * Count event id 0x0 in socket 1 with source filter = local non-CPU device and |
| destination filter = remote memory:: |
| |
| perf stat -a -e nvidia_ucf_pmu_1/event=0x0,src_loc_noncpu=0x1,dst_rem=0x1/ |
| |
| PCIE PMU |
| -------- |
| |
| This PMU is located in the SOC fabric connecting the PCIE root complex (RC) and |
| the memory subsystem. It monitors all read/write traffic from the root port(s) |
| or a particular BDF in a PCIE RC to local or remote memory. There is one PMU per |
| PCIE RC in the SoC. Each RC can have up to 16 lanes that can be bifurcated into |
| up to 8 root ports. The traffic from each root port can be filtered using RP or |
| BDF filter. For example, specifying "src_rp_mask=0xFF" means the PMU counter will |
| capture traffic from all RPs. Please see below for more details. |
| |
| The events and configuration options of this PMU device are described in sysfs, |
| see /sys/bus/event_source/devices/nvidia_pcie_pmu_<socket-id>_rc_<pcie-rc-id>. |
| |
| The events in this PMU can be used to measure bandwidth, utilization, and |
| latency: |
| |
| * rd_req: count the number of read requests by PCIE device. |
| * wr_req: count the number of write requests by PCIE device. |
| * rd_bytes: count the number of bytes transferred by rd_req. |
| * wr_bytes: count the number of bytes transferred by wr_req. |
| * rd_cum_outs: count outstanding rd_req each cycle. |
| * cycles: count the clock cycles of SOC fabric connected to the PCIE interface. |
| |
| The average bandwidth is calculated as:: |
| |
| AVG_RD_BANDWIDTH_IN_GBPS = RD_BYTES / ELAPSED_TIME_IN_NS |
| AVG_WR_BANDWIDTH_IN_GBPS = WR_BYTES / ELAPSED_TIME_IN_NS |
| |
| The average request rate is calculated as:: |
| |
| AVG_RD_REQUEST_RATE = RD_REQ / CYCLES |
| AVG_WR_REQUEST_RATE = WR_REQ / CYCLES |
| |
| |
| The average latency is calculated as:: |
| |
| FREQ_IN_GHZ = CYCLES / ELAPSED_TIME_IN_NS |
| AVG_LATENCY_IN_CYCLES = RD_CUM_OUTS / RD_REQ |
| AVERAGE_LATENCY_IN_NS = AVG_LATENCY_IN_CYCLES / FREQ_IN_GHZ |
| |
| The PMU events can be filtered based on the traffic source and destination. |
| The source filter indicates the PCIE devices that will be monitored. The |
| destination filter specifies the destination memory type, e.g. local system |
| memory (CMEM), local GPU memory (GMEM), or remote memory. The local/remote |
| classification of the destination filter is based on the home socket of the |
| address, not where the data actually resides. These filters can be found in |
| /sys/bus/event_source/devices/nvidia_pcie_pmu_<socket-id>_rc_<pcie-rc-id>/format/. |
| |
| The list of event filters: |
| |
| * Source filter: |
| |
| * src_rp_mask: bitmask of root ports that will be monitored. Each bit in this |
| bitmask represents the RP index in the RC. If the bit is set, all devices under |
| the associated RP will be monitored. E.g "src_rp_mask=0xF" will monitor |
| devices in root port 0 to 3. |
| * src_bdf: the BDF that will be monitored. This is a 16-bit value that |
| follows formula: (bus << 8) + (device << 3) + (function). For example, the |
| value of BDF 27:01.1 is 0x2781. |
| * src_bdf_en: enable the BDF filter. If this is set, the BDF filter value in |
| "src_bdf" is used to filter the traffic. |
| |
| Note that Root-Port and BDF filters are mutually exclusive and the PMU in |
| each RC can only have one BDF filter for the whole counters. If BDF filter |
| is enabled, the BDF filter value will be applied to all events. |
| |
| * Destination filter: |
| |
| * dst_loc_cmem: if set, count events to local system memory (CMEM) address |
| * dst_loc_gmem: if set, count events to local GPU memory (GMEM) address |
| * dst_loc_pcie_p2p: if set, count events to local PCIE peer address |
| * dst_loc_pcie_cxl: if set, count events to local CXL memory address |
| * dst_rem: if set, count events to remote memory address |
| |
| If the source filter is not specified, the PMU will count events from all root |
| ports. If the destination filter is not specified, the PMU will count events |
| to all destinations. |
| |
| Example usage: |
| |
| * Count event id 0x0 from root port 0 of PCIE RC-0 on socket 0 targeting all |
| destinations:: |
| |
| perf stat -a -e nvidia_pcie_pmu_0_rc_0/event=0x0,src_rp_mask=0x1/ |
| |
| * Count event id 0x1 from root port 0 and 1 of PCIE RC-1 on socket 0 and |
| targeting just local CMEM of socket 0:: |
| |
| perf stat -a -e nvidia_pcie_pmu_0_rc_1/event=0x1,src_rp_mask=0x3,dst_loc_cmem=0x1/ |
| |
| * Count event id 0x2 from root port 0 of PCIE RC-2 on socket 1 targeting all |
| destinations:: |
| |
| perf stat -a -e nvidia_pcie_pmu_1_rc_2/event=0x2,src_rp_mask=0x1/ |
| |
| * Count event id 0x3 from root port 0 and 1 of PCIE RC-3 on socket 1 and |
| targeting just local CMEM of socket 1:: |
| |
| perf stat -a -e nvidia_pcie_pmu_1_rc_3/event=0x3,src_rp_mask=0x3,dst_loc_cmem=0x1/ |
| |
| * Count event id 0x4 from BDF 01:01.0 of PCIE RC-4 on socket 0 targeting all |
| destinations:: |
| |
| perf stat -a -e nvidia_pcie_pmu_0_rc_4/event=0x4,src_bdf=0x0180,src_bdf_en=0x1/ |
| |
| .. _NVIDIA_T410_PCIE_PMU_RC_Mapping_Section: |
| |
| Mapping the RC# to lspci segment number |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| |
| Mapping the RC# to lspci segment number can be non-trivial; hence a new NVIDIA |
| Designated Vendor Specific Capability (DVSEC) register is added into the PCIE config space |
| for each RP. This DVSEC has vendor id "10de" and DVSEC id of "0x4". The DVSEC register |
| contains the following information to map PCIE devices under the RP back to its RC# : |
| |
| - Bus# (byte 0xc) : bus number as reported by the lspci output |
| - Segment# (byte 0xd) : segment number as reported by the lspci output |
| - RP# (byte 0xe) : port number as reported by LnkCap attribute from lspci for a device with Root Port capability |
| - RC# (byte 0xf): root complex number associated with the RP |
| - Socket# (byte 0x10): socket number associated with the RP |
| |
| Example script for mapping lspci BDF to RC# and socket#:: |
| |
| #!/bin/bash |
| while read bdf rest; do |
| dvsec4_reg=$(lspci -vv -s $bdf | awk ' |
| /Designated Vendor-Specific: Vendor=10de ID=0004/ { |
| match($0, /\[([0-9a-fA-F]+)/, arr); |
| print "0x" arr[1]; |
| exit |
| } |
| ') |
| if [ -n "$dvsec4_reg" ]; then |
| bus=$(setpci -s $bdf $(printf '0x%x' $((${dvsec4_reg} + 0xc))).b) |
| segment=$(setpci -s $bdf $(printf '0x%x' $((${dvsec4_reg} + 0xd))).b) |
| rp=$(setpci -s $bdf $(printf '0x%x' $((${dvsec4_reg} + 0xe))).b) |
| rc=$(setpci -s $bdf $(printf '0x%x' $((${dvsec4_reg} + 0xf))).b) |
| socket=$(setpci -s $bdf $(printf '0x%x' $((${dvsec4_reg} + 0x10))).b) |
| echo "$bdf: Bus=$bus, Segment=$segment, RP=$rp, RC=$rc, Socket=$socket" |
| fi |
| done < <(lspci -d 10de:) |
| |
| Example output:: |
| |
| 0001:00:00.0: Bus=00, Segment=01, RP=00, RC=00, Socket=00 |
| 0002:80:00.0: Bus=80, Segment=02, RP=01, RC=01, Socket=00 |
| 0002:a0:00.0: Bus=a0, Segment=02, RP=02, RC=01, Socket=00 |
| 0002:c0:00.0: Bus=c0, Segment=02, RP=03, RC=01, Socket=00 |
| 0002:e0:00.0: Bus=e0, Segment=02, RP=04, RC=01, Socket=00 |
| 0003:00:00.0: Bus=00, Segment=03, RP=00, RC=02, Socket=00 |
| 0004:00:00.0: Bus=00, Segment=04, RP=00, RC=03, Socket=00 |
| 0005:00:00.0: Bus=00, Segment=05, RP=00, RC=04, Socket=00 |
| 0005:40:00.0: Bus=40, Segment=05, RP=01, RC=04, Socket=00 |
| 0005:c0:00.0: Bus=c0, Segment=05, RP=02, RC=04, Socket=00 |
| 0006:00:00.0: Bus=00, Segment=06, RP=00, RC=05, Socket=00 |
| 0009:00:00.0: Bus=00, Segment=09, RP=00, RC=00, Socket=01 |
| 000a:80:00.0: Bus=80, Segment=0a, RP=01, RC=01, Socket=01 |
| 000a:a0:00.0: Bus=a0, Segment=0a, RP=02, RC=01, Socket=01 |
| 000a:e0:00.0: Bus=e0, Segment=0a, RP=03, RC=01, Socket=01 |
| 000b:00:00.0: Bus=00, Segment=0b, RP=00, RC=02, Socket=01 |
| 000c:00:00.0: Bus=00, Segment=0c, RP=00, RC=03, Socket=01 |
| 000d:00:00.0: Bus=00, Segment=0d, RP=00, RC=04, Socket=01 |
| 000d:40:00.0: Bus=40, Segment=0d, RP=01, RC=04, Socket=01 |
| 000d:c0:00.0: Bus=c0, Segment=0d, RP=02, RC=04, Socket=01 |
| 000e:00:00.0: Bus=00, Segment=0e, RP=00, RC=05, Socket=01 |
| |
| PCIE-TGT PMU |
| ------------ |
| |
| This PMU is located in the SOC fabric connecting the PCIE root complex (RC) and |
| the memory subsystem. It monitors traffic targeting PCIE BAR and CXL HDM ranges. |
| There is one PCIE-TGT PMU per PCIE RC in the SoC. Each RC in Tegra410 SoC can |
| have up to 16 lanes that can be bifurcated into up to 8 root ports (RP). The PMU |
| provides RP filter to count PCIE BAR traffic to each RP and address filter to |
| count access to PCIE BAR or CXL HDM ranges. The details of the filters are |
| described in the following sections. |
| |
| Mapping the RC# to lspci segment number is similar to the PCIE PMU. Please see |
| :ref:`NVIDIA_T410_PCIE_PMU_RC_Mapping_Section` for more info. |
| |
| The events and configuration options of this PMU device are available in sysfs, |
| see /sys/bus/event_source/devices/nvidia_pcie_tgt_pmu_<socket-id>_rc_<pcie-rc-id>. |
| |
| The events in this PMU can be used to measure bandwidth and utilization: |
| |
| * rd_req: count the number of read requests to PCIE. |
| * wr_req: count the number of write requests to PCIE. |
| * rd_bytes: count the number of bytes transferred by rd_req. |
| * wr_bytes: count the number of bytes transferred by wr_req. |
| * cycles: count the clock cycles of SOC fabric connected to the PCIE interface. |
| |
| The average bandwidth is calculated as:: |
| |
| AVG_RD_BANDWIDTH_IN_GBPS = RD_BYTES / ELAPSED_TIME_IN_NS |
| AVG_WR_BANDWIDTH_IN_GBPS = WR_BYTES / ELAPSED_TIME_IN_NS |
| |
| The average request rate is calculated as:: |
| |
| AVG_RD_REQUEST_RATE = RD_REQ / CYCLES |
| AVG_WR_REQUEST_RATE = WR_REQ / CYCLES |
| |
| The PMU events can be filtered based on the destination root port or target |
| address range. Filtering based on RP is only available for PCIE BAR traffic. |
| Address filter works for both PCIE BAR and CXL HDM ranges. These filters can be |
| found in sysfs, see |
| /sys/bus/event_source/devices/nvidia_pcie_tgt_pmu_<socket-id>_rc_<pcie-rc-id>/format/. |
| |
| Destination filter settings: |
| |
| * dst_rp_mask: bitmask to select the root port(s) to monitor. E.g. "dst_rp_mask=0xFF" |
| corresponds to all root ports (from 0 to 7) in the PCIE RC. Note that this filter is |
| only available for PCIE BAR traffic. |
| * dst_addr_base: BAR or CXL HDM filter base address. |
| * dst_addr_mask: BAR or CXL HDM filter address mask. |
| * dst_addr_en: enable BAR or CXL HDM address range filter. If this is set, the |
| address range specified by "dst_addr_base" and "dst_addr_mask" will be used to filter |
| the PCIE BAR and CXL HDM traffic address. The PMU uses the following comparison |
| to determine if the traffic destination address falls within the filter range:: |
| |
| (txn's addr & dst_addr_mask) == (dst_addr_base & dst_addr_mask) |
| |
| If the comparison succeeds, then the event will be counted. |
| |
| If the destination filter is not specified, the RP filter will be configured by default |
| to count PCIE BAR traffic to all root ports. |
| |
| Example usage: |
| |
| * Count event id 0x0 to root port 0 and 1 of PCIE RC-0 on socket 0:: |
| |
| perf stat -a -e nvidia_pcie_tgt_pmu_0_rc_0/event=0x0,dst_rp_mask=0x3/ |
| |
| * Count event id 0x1 for accesses to PCIE BAR or CXL HDM address range |
| 0x10000 to 0x100FF on socket 0's PCIE RC-1:: |
| |
| perf stat -a -e nvidia_pcie_tgt_pmu_0_rc_1/event=0x1,dst_addr_base=0x10000,dst_addr_mask=0xFFF00,dst_addr_en=0x1/ |
| |
| CPU Memory (CMEM) Latency PMU |
| ----------------------------- |
| |
| This PMU monitors latency events of memory read requests from the edge of the |
| Unified Coherence Fabric (UCF) to local CPU DRAM: |
| |
| * RD_REQ counters: count read requests (32B per request). |
| * RD_CUM_OUTS counters: accumulated outstanding request counter, which track |
| how many cycles the read requests are in flight. |
| * CYCLES counter: counts the number of elapsed cycles. |
| |
| The average latency is calculated as:: |
| |
| FREQ_IN_GHZ = CYCLES / ELAPSED_TIME_IN_NS |
| AVG_LATENCY_IN_CYCLES = RD_CUM_OUTS / RD_REQ |
| AVERAGE_LATENCY_IN_NS = AVG_LATENCY_IN_CYCLES / FREQ_IN_GHZ |
| |
| The events and configuration options of this PMU device are described in sysfs, |
| see /sys/bus/event_source/devices/nvidia_cmem_latency_pmu_<socket-id>. |
| |
| Example usage:: |
| |
| perf stat -a -e '{nvidia_cmem_latency_pmu_0/rd_req/,nvidia_cmem_latency_pmu_0/rd_cum_outs/,nvidia_cmem_latency_pmu_0/cycles/}' |
| |
| NVLink-C2C PMU |
| -------------- |
| |
| This PMU monitors latency events of memory read/write requests that pass through |
| the NVIDIA Chip-to-Chip (C2C) interface. Bandwidth events are not available |
| in this PMU, unlike the C2C PMU in Grace (Tegra241 SoC). |
| |
| The events and configuration options of this PMU device are available in sysfs, |
| see /sys/bus/event_source/devices/nvidia_nvlink_c2c_pmu_<socket-id>. |
| |
| The list of events: |
| |
| * IN_RD_CUM_OUTS: accumulated outstanding request (in cycles) of incoming read requests. |
| * IN_RD_REQ: the number of incoming read requests. |
| * IN_WR_CUM_OUTS: accumulated outstanding request (in cycles) of incoming write requests. |
| * IN_WR_REQ: the number of incoming write requests. |
| * OUT_RD_CUM_OUTS: accumulated outstanding request (in cycles) of outgoing read requests. |
| * OUT_RD_REQ: the number of outgoing read requests. |
| * OUT_WR_CUM_OUTS: accumulated outstanding request (in cycles) of outgoing write requests. |
| * OUT_WR_REQ: the number of outgoing write requests. |
| * CYCLES: NVLink-C2C interface cycle counts. |
| |
| The incoming events count the reads/writes from remote device to the SoC. |
| The outgoing events count the reads/writes from the SoC to remote device. |
| |
| The sysfs /sys/bus/event_source/devices/nvidia_nvlink_c2c_pmu_<socket-id>/peer |
| contains the information about the connected device. |
| |
| When the C2C interface is connected to GPU(s), the user can use the |
| "gpu_mask" parameter to filter traffic to/from specific GPU(s). Each bit represents the GPU |
| index, e.g. "gpu_mask=0x1" corresponds to GPU 0 and "gpu_mask=0x3" is for GPU 0 and 1. |
| The PMU will monitor all GPUs by default if not specified. |
| |
| When connected to another SoC, only the read events are available. |
| |
| The events can be used to calculate the average latency of the read/write requests:: |
| |
| C2C_FREQ_IN_GHZ = CYCLES / ELAPSED_TIME_IN_NS |
| |
| IN_RD_AVG_LATENCY_IN_CYCLES = IN_RD_CUM_OUTS / IN_RD_REQ |
| IN_RD_AVG_LATENCY_IN_NS = IN_RD_AVG_LATENCY_IN_CYCLES / C2C_FREQ_IN_GHZ |
| |
| IN_WR_AVG_LATENCY_IN_CYCLES = IN_WR_CUM_OUTS / IN_WR_REQ |
| IN_WR_AVG_LATENCY_IN_NS = IN_WR_AVG_LATENCY_IN_CYCLES / C2C_FREQ_IN_GHZ |
| |
| OUT_RD_AVG_LATENCY_IN_CYCLES = OUT_RD_CUM_OUTS / OUT_RD_REQ |
| OUT_RD_AVG_LATENCY_IN_NS = OUT_RD_AVG_LATENCY_IN_CYCLES / C2C_FREQ_IN_GHZ |
| |
| OUT_WR_AVG_LATENCY_IN_CYCLES = OUT_WR_CUM_OUTS / OUT_WR_REQ |
| OUT_WR_AVG_LATENCY_IN_NS = OUT_WR_AVG_LATENCY_IN_CYCLES / C2C_FREQ_IN_GHZ |
| |
| Example usage: |
| |
| * Count incoming traffic from all GPUs connected via NVLink-C2C:: |
| |
| perf stat -a -e nvidia_nvlink_c2c_pmu_0/in_rd_req/ |
| |
| * Count incoming traffic from GPU 0 connected via NVLink-C2C:: |
| |
| perf stat -a -e nvidia_nvlink_c2c_pmu_0/in_rd_cum_outs,gpu_mask=0x1/ |
| |
| * Count incoming traffic from GPU 1 connected via NVLink-C2C:: |
| |
| perf stat -a -e nvidia_nvlink_c2c_pmu_0/in_rd_cum_outs,gpu_mask=0x2/ |
| |
| * Count outgoing traffic to all GPUs connected via NVLink-C2C:: |
| |
| perf stat -a -e nvidia_nvlink_c2c_pmu_0/out_rd_req/ |
| |
| * Count outgoing traffic to GPU 0 connected via NVLink-C2C:: |
| |
| perf stat -a -e nvidia_nvlink_c2c_pmu_0/out_rd_cum_outs,gpu_mask=0x1/ |
| |
| * Count outgoing traffic to GPU 1 connected via NVLink-C2C:: |
| |
| perf stat -a -e nvidia_nvlink_c2c_pmu_0/out_rd_cum_outs,gpu_mask=0x2/ |
| |
| NV-CLink PMU |
| ------------ |
| |
| This PMU monitors latency events of memory read requests that pass through |
| the NV-CLINK interface. Bandwidth events are not available in this PMU. |
| In Tegra410 SoC, the NV-CLink interface is used to connect to another Tegra410 |
| SoC and this PMU only counts read traffic. |
| |
| The events and configuration options of this PMU device are available in sysfs, |
| see /sys/bus/event_source/devices/nvidia_nvclink_pmu_<socket-id>. |
| |
| The list of events: |
| |
| * IN_RD_CUM_OUTS: accumulated outstanding request (in cycles) of incoming read requests. |
| * IN_RD_REQ: the number of incoming read requests. |
| * OUT_RD_CUM_OUTS: accumulated outstanding request (in cycles) of outgoing read requests. |
| * OUT_RD_REQ: the number of outgoing read requests. |
| * CYCLES: NV-CLINK interface cycle counts. |
| |
| The incoming events count the reads from remote device to the SoC. |
| The outgoing events count the reads from the SoC to remote device. |
| |
| The events can be used to calculate the average latency of the read requests:: |
| |
| CLINK_FREQ_IN_GHZ = CYCLES / ELAPSED_TIME_IN_NS |
| |
| IN_RD_AVG_LATENCY_IN_CYCLES = IN_RD_CUM_OUTS / IN_RD_REQ |
| IN_RD_AVG_LATENCY_IN_NS = IN_RD_AVG_LATENCY_IN_CYCLES / CLINK_FREQ_IN_GHZ |
| |
| OUT_RD_AVG_LATENCY_IN_CYCLES = OUT_RD_CUM_OUTS / OUT_RD_REQ |
| OUT_RD_AVG_LATENCY_IN_NS = OUT_RD_AVG_LATENCY_IN_CYCLES / CLINK_FREQ_IN_GHZ |
| |
| Example usage: |
| |
| * Count incoming read traffic from remote SoC connected via NV-CLINK:: |
| |
| perf stat -a -e nvidia_nvclink_pmu_0/in_rd_req/ |
| |
| * Count outgoing read traffic to remote SoC connected via NV-CLINK:: |
| |
| perf stat -a -e nvidia_nvclink_pmu_0/out_rd_req/ |
| |
| NV-DLink PMU |
| ------------ |
| |
| This PMU monitors latency events of memory read requests that pass through |
| the NV-DLINK interface. Bandwidth events are not available in this PMU. |
| In Tegra410 SoC, this PMU only counts CXL memory read traffic. |
| |
| The events and configuration options of this PMU device are available in sysfs, |
| see /sys/bus/event_source/devices/nvidia_nvdlink_pmu_<socket-id>. |
| |
| The list of events: |
| |
| * IN_RD_CUM_OUTS: accumulated outstanding read requests (in cycles) to CXL memory. |
| * IN_RD_REQ: the number of read requests to CXL memory. |
| * CYCLES: NV-DLINK interface cycle counts. |
| |
| The events can be used to calculate the average latency of the read requests:: |
| |
| DLINK_FREQ_IN_GHZ = CYCLES / ELAPSED_TIME_IN_NS |
| |
| IN_RD_AVG_LATENCY_IN_CYCLES = IN_RD_CUM_OUTS / IN_RD_REQ |
| IN_RD_AVG_LATENCY_IN_NS = IN_RD_AVG_LATENCY_IN_CYCLES / DLINK_FREQ_IN_GHZ |
| |
| Example usage: |
| |
| * Count read events to CXL memory:: |
| |
| perf stat -a -e '{nvidia_nvdlink_pmu_0/in_rd_req/,nvidia_nvdlink_pmu_0/in_rd_cum_outs/}' |