| What: /sys/bus/iio/devices/iio:deviceX/in_volumeflow_medium | |
| What: /sys/bus/iio/devices/iio:deviceX/in_volumeflowY_medium | |
| KernelVersion: 7.3 | |
| Contact: linux-iio@vger.kernel.org | |
| Description: | |
| The calibration medium the flow sensor uses to convert its | |
| raw reading into a volumetric flow rate. Liquid flow sensors | |
| are factory-calibrated per medium, so the selected medium has | |
| to match the fluid actually flowing through the sensor for the | |
| reported flow rate to be correct. | |
| Reading returns the currently active medium; writing one of the | |
| strings listed in in_volumeflow_medium_available selects it. | |
| What: /sys/bus/iio/devices/iio:deviceX/in_volumeflow_medium_available | |
| What: /sys/bus/iio/devices/iio:deviceX/in_volumeflowY_medium_available | |
| KernelVersion: 7.3 | |
| Contact: linux-iio@vger.kernel.org | |
| Description: | |
| Space separated list of the calibration media supported by the | |
| device, e.g. "water ipa". |